BUILDING ENVELOPES
We are committed to evolving methods that improve the inherent passive gains within a building's enclosure.
BUILDING ENVELOPE COMISSIONING (BECx)
As Building Envelope Commissioning Providers (BECxP), we make sure your enclosure works for you, not against you. From early design through final verification, we ensure your building’s envelope delivers long-term efficiency, durability, and comfort.
Our role is to coordinate across disciplines—ensuring that critical sustainability and performance measures are fully integrated, never overlooked. We simplify the complex commissioning process, helping clients avoid future rework, reduce operating costs, and realize the full potential of their building enclosure.
Envelope Commissioning helps projects meet efficiency goals, reduce operating costs, and qualify for funding opportunities— all while delivering a tighter, better-performing building.
LEARN MORE ABOUT BECxP
CRITICAL FACADE EXAMINATIONS
Stay ahead of code requirements and protect your building’s long-term performance. HUSARCH delivers comprehensive facade inspection services for high-rise buildings, with certified swing stage access and a licensed architectural team.
Our team handles all logistics—from equipment to certification—so you can focus on what matters: a safe, efficient, code-compliant building.
Critical Examinations
(Required in Chicago every 4 years)
Full swing stage setup and certified access
Up-close inspection of entire facade or designated sample areas
Identification of openings for masonry investigation
Forensic review of structural or moisture issues
Clear, actionable repair recommendations
Ongoing Inspections
(Periodic maintenance checks)
Ground-level review of full building envelope
Early detection of deterioration or damage
Summary report with next-step recommendations
DRAWING QUALITY CONTROL (QC)
We help project teams avoid costly rework by identifying risks before construction begins. Our Building Envelope Drawing QC process combines rigorous code checks with detailed envelope analysis to ensure tighter, more resilient buildings.
What We Review:
Code compliance and coordination spot checks
Inconsistencies across drawings and specifications
All exterior assemblies: roof, walls, foundations, and fenestration
Insulation type, placement, and thickness
Glazing performance (U-values and Solar Heat Gain Coefficients)
Thermal continuity and envelope performance
Air and vapor barrier alignment and integrity
Envelope behavior in response to environmental conditions
Consistency with design intent and project specifications